Search results for "Ion trap"

showing 10 items of 246 documents

High-resolution rovibrational spectroscopy of c-C3H2+: The ν7 C–H antisymmetric stretching band

2020

Abstract The ν 7 antisymmetric C–H stretching fundamental of c- C 3 H 2 + has been characterized in a cryogenic 22-pole ion trap by a novel type of action spectroscopy, in which the rovibrational excitation of c- C 3 H 2 + is detected as a slowing down of the low-temperature reaction c- C 3 H 2 +  + H2 → C 3 H 3 + + H. Ninety-one rovibrational transitions with partly resolved fine structure doublets were measured in high resolution. Supported by high-level quantum chemical calculations, spectroscopic parameters were determined by fitting the observed lines with an effective Hamiltonian for an asymmetric rotor in a doublet electronic ground state, X ˜ A 1 2 , yielding a band origin at 3113.6…

010405 organic chemistryAntisymmetric relationChemistryOrganic ChemistryRotational–vibrational spectroscopy010402 general chemistry01 natural sciencesMolecular physics0104 chemical sciencesAnalytical ChemistryInorganic Chemistrysymbols.namesakesymbolsMoleculeIon trapGround stateHamiltonian (quantum mechanics)SpectroscopySpectroscopyExcitationJournal of Molecular Structure
researchProduct

Studies on the Reduction of [(C 5 Me 5 ) 2 Mo 2 O 5 ] in Methanol/Water/Acetate Solutions by On‐Line Electrochemical Flowcell and Electrospray Mass S…

2003

The complex [Cp*2Mo2O5] (Cp* = η5-C5Me5) and its electrochemical reduction products in acetic acid/acetate-buffered (pH = 4.0) water/methanol solutions were investigated by combined electrochemical (EC) flowcell and on-line electrospray ionization mass spectrometry (ESI-MS). Mono-, di-, tri-, and tetranuclear organometallic molybdenum oxides were identified in the starting solution. The effect of the relevant ESI-MS parameters (ionic mode, heated capillary voltage, and heated capillary temperature) and of the concentration on the observed distribution of ions in the mass spectrometer was studied in order to minimize side reactions in the ESI chamber. It was verified that reduction in the ES…

010405 organic chemistryElectrospray ionizationInorganic chemistrychemistry.chemical_element010402 general chemistryMass spectrometryElectrochemistry01 natural sciences0104 chemical sciencesInorganic Chemistrychemistry.chemical_compoundAcetic acidchemistryOxidation stateMolybdenumMethanolIon trapEuropean Journal of Inorganic Chemistry
researchProduct

Importance of meteorological variables for aeroplankton dispersal in an urban environment

2016

Passive wind dispersal is one of the major mechanisms through which organisms disperse and colonize new areas. The detailed comprehension of which factors affect this process may help to preserve its efficiency for years to come. This is especially important in the current context of climate change, which may seriously alter weather regimes that drive dispersal, and is crucial in urban contexts, where biodiversity is dramatically threatened by pollution and fragmentation of natural patches. Despite its interest, the analysis of factors affecting aeroplankton dispersal in urban environments is rare in literature. We sampled aeroplankton community uninterruptedly every 4 hours from 17th May t…

0106 biological sciencesSuction trapAeroplanktonbiologyEcologyJohnson-Taylor suction trap aeroplankton arthropods passive transport meteorological variablesSampling (statistics)ORDER HYMENOPTERAbiology.organism_classification010603 evolutionary biology01 natural sciences010602 entomologySettore AGR/11 - Entomologia Generale E ApplicataBiological dispersalAnimal Science and ZoologyAgaonidaeUrban environment
researchProduct

Revealing Anisotropy in a Paul Trap Through Berry Phase

2006

When an ion confined in an anisotropic bidimensional Paul trap is subjected to a laser beam oriented along an arbitrary direction, the interaction between its electronic and vibrational degrees of freedom is described by a time-dependent Hamiltonian model as a consequence of the lack of symmetry. Appropriately choosing the laser frequency, the Hamiltonian model turns out to be sinusoidally oscillating at the difference between the proper frequencies of the center of mass of the ion. Thus, if the anisotropy of the trap is sufficiently small, the evolution of the system can be considered as adiabatic. In the context of this physical situation we have calculated the Berry phase acquired in a c…

Adiabatic theoremPhysicssymbols.namesakeNuclear magnetic resonanceGeometric phaseQuantum mechanicsIsotropysymbolsObservableIon trapAdiabatic processAnisotropyHamiltonian (quantum mechanics)
researchProduct

Application of ultra-high pressure liquid chromatography linear ion-trap orbitrap to qualitative and quantitative assessment of pesticide residues

2014

Abstract The analysis of pesticides residues using a last generation high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometer (LTQ-Orbitrap-MS) was explored. Pesticides were extracted from fruits, fish, bees and sediments by QuEChERS and from water by solid-phase with Oasis HLB cartridges. Ultra-high pressure liquid chromatography (UHPLC)–LTQ-Orbitrap mass spectrometer acquired full scan MS data for quantification, and data dependent (dd) MS 2 and MS 3 product ion spectra for identification and/or confirmation. The regression coefficients ( r 2 ) for the calibration curves (two order of magnitude up to the lowest calibration level) in the study were ≥0.99. Th…

AnalyteMeatCalibration curveAnalytical chemistryOrbitrapQuechersMass spectrometryBiochemistryMass SpectrometryAnalytical Chemistrylaw.inventionlawAnimalsQuadrupole ion trapChromatography High Pressure LiquidChromatographyPesticide residueChemistryOrganic ChemistryFishesPesticide ResiduesGeneral MedicineBeesPesticideFruitEnvironmental PollutantsWater Pollutants ChemicalJournal of Chromatography A
researchProduct

Applicability of hybrid linear ion trap-high resolution mass spectrometry and quadrupole-linear ion trap-mass spectrometry for mycotoxin analysis in …

2012

Abstract Recent developments in mass spectrometers have created a paradoxical situation; different mass spectrometers are available, each of them with their specific strengths and drawbacks. Hybrid instruments try to unify several advantages in one instrument. In this study two of wide-used hybrid instruments were compared: hybrid quadrupole-linear ion trap-mass spectrometry (QTRAP ® ) and the hybrid linear ion trap-high resolution mass spectrometry (LTQ-Orbitrap ® ). Both instruments were applied to detect the presence of 18 selected mycotoxins in baby food. Analytical parameters were validated according to 2002/657/CE. Limits of quantification (LOQs) obtained by QTRAP ® instrument ranged …

Analytical chemistryMass spectrometryOrbitrapBiochemistryMass SpectrometryAnalytical ChemistryIonlaw.inventionBaby foodchemistry.chemical_compoundlawLimit of DetectionMSPDHumansQuadrupole ion trapMycotoxinQTRAPChromatography High Pressure LiquidChromatographyBaby foodOrganic ChemistryInfantGeneral MedicineMycotoxinsOrbitrapchemistryQuadrupoleInfant FoodJournal of chromatography. A
researchProduct

Experimental verification of position-dependent angular-momentum selection rules for absorption of twisted light by a bound electron

2018

We analyze the multipole excitation of atoms with twisted light, i.e., by a vortex light field that carries orbital angular momentum. A single trapped $^{40}$Ca$^+$ ion serves as a localized and positioned probe of the exciting field. We drive the $S_{1/2} \to D_{5/2}$ transition and observe the relative strengths of different transitions, depending on the ion's transversal position with respect to the center of the vortex light field. On the other hand, transition amplitudes are calculated for a twisted light field in form of a Bessel beam, a Bessel-Gauss and a Gauss-Laguerre mode. Analyzing experimental obtained transition amplitudes we find agreement with the theoretical predictions at a…

Angular momentumField (physics)Atomic Physics (physics.atom-ph)Ciencias FísicasGeneral Physics and AstronomyFOS: Physical sciencesOPTICAL ANGULAR MOMENTUM01 natural sciencesOPTICAL VORTICESPhysics - Atomic PhysicsRABI OSCILLATIONS010309 optics//purl.org/becyt/ford/1 [https]0103 physical sciences010306 general physicsION TRAPSÓpticaPhysicsQuantum Physics//purl.org/becyt/ford/1.3 [https]VortexBessel beamQUANTUM SELECTION RULESAtomic physicsMultipole expansionQuantum Physics (quant-ph)Optical vortexCIENCIAS NATURALES Y EXACTASLight fieldExcitationPhysics - OpticsOptics (physics.optics)
researchProduct

X-ray measurements of charge transfer reactions involving cold, very highly charged ions

1999

The magnetic trapping mode of the Livermore high-energy Electron Beam Ion Trap is exploited to study charge transfer reactions between cold (few eV/amu) highly charged ions and gases. By selectively puffing neutral gases and monitoring the x-ray emission, state-selective measurements of the charge transfer reaction channels are possible. The observed K-shell x-ray spectra show prominent emission from high-n levels decaying to the n = 1 ground level, which is enabled by electron capture into states with low orbital angular momentum. A comparison with modeling calculations, therefore, allows a determination of the range of principal and angular momentum quantum numbers involved in the reactio…

Angular momentumRange (particle radiation)Materials scienceElectron captureTotal angular momentum quantum numberCharge (physics)Atomic physicsCondensed Matter PhysicsMathematical PhysicsAtomic and Molecular Physics and OpticsSpectral lineElectron beam ion trapIon
researchProduct

Large-scale migration synchrony between parasitoids and their host

2015

1. Parasitoids are a valuable group for conservation biological control. In their role as regulators of aphid pests, it is critical that their lifecycle is synchronised with their hosts in both space and time. This is because a synchronised parasitoid community is more likely to strengthen the overall conservation biological control effect, thus damping aphid numbers and preventing potential outbreaks. One component of this host–parasitoid system was examined, that of migration, and the hypothesis that peak summer parasitoid and host migrations are synchronised in time was tested. 2. Sitobion avenae Fabricius and six associated parasitoids were sampled from 1976 to 2013 using 12.2-m suction…

AphidSuction trapEcologybiologyPhenologyEcologyHost (biology)fungiBiological pest controlfood and beveragesbiology.organism_classificationParasitoidSitobion avenaeInsect ScienceAphidiinaeEntomology
researchProduct

Prospects of Ion Chemical Reactions with Heavy Elements in the Gas Phase

2001

Heavy element chemistry is related to the fundamental interest that lies in exploring the upper limits of the periodic table. Chemical properties of the heaviest elements have already been studied at single atoms in aqueous solutions and in the gas phase up to an atomic number Z = 107. These techniques allow to study nuclides with half lives as short as about 1 s. Next generation chemistry experiments could be envisaged with an ion trap technique already developed for stable isotopes. At very low production rates in the order of 1 per 100 s and/or half lives as short as about 10 ms, the ion-molecule reactions can be studied in a buffer gas cell, in which the heavy elements are stopped and t…

Aqueous solutionChemistryStable isotope ratioBuffer gasNuclideAtomic numberIon trapAtomic physicsChemical reactionIon
researchProduct